[ZAHM & NAGEL] CO2 PURITY TESTER 10003 (CASE X) 10004 (CASE O) 이미지 확대 보기
  • [ZAHM & NAGEL] CO2 PURITY TESTER 10003 (CASE X) 10004 (CASE O)

[ZAHM & NAGEL] CO2 PURITY TESTER 10003 (CASE X) 10004 (CASE O)

공유
판매가
견적문의
구매제한
옵션당 최소 1개
구매혜택
할인 : 적립 마일리지 :
배송비
0원 조건별배송
택배
 / 주문시결제(선결제)
방문 수령지 : 부산광역시 해운대구 우동1로20번가길 52-5(우동) 1층
상품코드
2549
모델명
10003 / 10004
브랜드
ZAHM & NAGEL
제조사
ZAHM & NAGEL
원산지
미국

상품상세정보

[ZAHM & NAGEL] CO2 PURITY TESTER

10003 (CASE X)

10004 (CASE O)


제품특징

Pressure Testers for Bottles & Cans

The Zahm CO² Gas Purity Tester is an improved absorption bottle designed to eliminate confusing cocks, hose connections, awkward manipulation, and the usual caustic spillage. It makes gas testing simple, fool-proof, clean, and highly accurate.


Description:

The Purity Tester consists of a caustic reservoir and calibrated absorption burette mounted to a PVC polished frame. The reservoir and burette are held to the frame with two neoprene covered mounting bands that are adjustable from the rear side of the frame. The absorption burettes are available in five different calibrations, with the standard burette graduated in tenths of one percent, the total being one percent of the volume of the burette. The caustic reservoir (10100) has a line indicating the level to which caustic solution should be added, which volume is slightly in excess of the capacity of the absorption burette. The line drawings should be used for identification of the Purity Tester parts. When inquiring about our gas purity testers, please specify which absorption burette you require.


Operating Instructions:

Caution: Caustic solution is used in the operation of this instrument. This solution may cause severe burns to the operator if not handled with care. Wear goggles and protective clothing while operating this instrument.

Preparation of Caustic Solution:

A 20% solution of either Potassium Hydroxide or Sodium Hydroxide is recommended for air testing*. To make a 20% solution slowly add 100 grams of Potassium or Sodium Hydroxide crystals to 500 cc’s of distilled water and store in a sealed jar. The Hydroxide solution may also be purchased from any laboratory or chemical supply company. *A weaker solution may be used, but the tests will take longer and fewer tests can be performed.

To Operate:

1. Attach a hose from the CO² gas supply that is to be tested to the nipple of the absorption burette. Use care when attaching the hose so as not to break the calibrated stem of the absorption burette. If using the 1/100th calibrated burette (10102) place your finger on top of the stem and push gently downward onto the support block to prevent the stem from breaking when attaching the hose. Make sure that the gas supply is regulated to below 10 psi before releasing gas into the Purity Tester.

2. Open both cocks (5005) and allow the gas to sweep through the absorption burette and caustic reservoir to completely displace air in the glassware. If preferred, the bulb may be first filled with water and the water displaced with the gas to be tested.

3. After the sample has been taken, close the cock on the absorption burette first and then close the cock on the caustic reservoir.

4. Pour the caustic solution into the reservoir to the line indicated on the bulb (approximately 105 cc).

5. Open the cock on the caustic reservoir and allow the solution to flow down into the absorption burette. Absorption of the CO² gas now takes place until only air in the sample remains, the small bubble of which may be moved around by tilting the Purity Tester slightly, thereby insuring complete absorption of the gas.

6. Close the cock on the caustic reservoir and turn the instrument 90 degrees so that it rests on its other frame side. In this position, the unabsorbed gas enters the calibrated neck where the volume is directly indicated. The percentage purity of CO² gas is 99% plus 1/10 of 1% for each division as indicated by the level above the bottom graduation (Using the standard absorption burette #10101). There are our other types of absorption burettes available which are listed below.

7. After the test is completed, empty the caustic solution from the Purity Tester. Place the Purity Tester over a container and open both cocks to allow the caustic to drain out. Rinse out all traces of caustic with warm water and dry the glassware before returning the tester to its case.


Absorption Burettes Available:

P/NGraduated InScale:
101010.10%99 to 100%
101020.01%99 to 100%
1.00%79 to 99%
101030.20%99 to 100%
101041.00%50 to 100%
101050.10%95 to 100 %

  

 PARTS


10003       Tester W/Stand, Bands, Reservoir & Burette (99 to 100% In 0.01%)
10102       Calibrated Absorption Burette (99 to 100%In 0.01%)
10100       Caustic Reservoir
5005         Teflon Stopcock
10108       Rubber Covered Band W/Nut (Fits #10102 Burette)
10109       Rubber Covered Band W/Nut (Fits #10100 Reservoir)
10111       Frame – 2Pc W/Center Block and support block
10113A     Protective Case
10114       Plastic Connector



배송안내

- 배송비 : 기본배송료는 2,500원 입니다. (도서,산간,오지 일부지역은 배송비가 추가될 수 있습니다)  50,000원 이상 구매시 무료배송입니다.

- 본 상품의 평균 배송일은 0일입니다.(입금 확인 후) 설치 상품의 경우 다소 늦어질수 있습니다.[배송예정일은 주문시점(주문순서)에 따른 유동성이 발생하므로 평균 배송일과는 차이가 발생할 수 있습니다.]

- 본 상품의 배송 가능일은 0일 입니다. 배송 가능일이란 본 상품을 주문 하신 고객님들께 상품 배송이 가능한 기간을 의미합니다. (단, 연휴 및 공휴일은 기간 계산시 제외하며 현금 주문일 경우 입금일 기준 입니다.)

교환 및 반품안내

- 상품 택(tag)제거 또는 개봉으로 상품 가치 훼손 시에는 상품수령후 7일 이내라도 교환 및 반품이 불가능합니다.

- 저단가 상품, 일부 특가 상품은 고객 변심에 의한 교환, 반품은 고객께서 배송비를 부담하셔야 합니다(제품의 하자,배송오류는 제외)

- 일부 상품은 신모델 출시, 부품가격 변동 등 제조사 사정으로 가격이 변동될 수 있습니다.

- 신발의 경우, 실외에서 착화하였거나 사용흔적이 있는 경우에는 교환/반품 기간내라도 교환 및 반품이 불가능 합니다.

- 수제화 중 개별 주문제작상품(굽높이,발볼,사이즈 변경)의 경우에는 제작완료, 인수 후에는 교환/반품기간내라도 교환 및 반품이 불가능 합니다. 

- 수입,명품 제품의 경우, 제품 및 본 상품의 박스 훼손, 분실 등으로 인한 상품 가치 훼손 시 교환 및 반품이 불가능 하오니, 양해 바랍니다.

- 일부 특가 상품의 경우, 인수 후에는 제품 하자나 오배송의 경우를 제외한 고객님의 단순변심에 의한 교환, 반품이 불가능할 수 있사오니, 각 상품의 상품상세정보를 꼭 참조하십시오. 

환불안내

- 상품 청약철회 가능기간은 상품 수령일로 부터 7일 이내 입니다.

AS안내

- 소비자분쟁해결 기준(공정거래위원회 고시)에 따라 피해를 보상받을 수 있습니다.

- A/S는 판매자에게 문의하시기 바랍니다.

이미지 확대보기[ZAHM & NAGEL] CO2 PURITY TESTER 10003 (CASE X) 10004 (CASE O)

[ZAHM & NAGEL] CO2 PURITY TESTER 10003 (CASE X) 10004 (CASE O)
  • [ZAHM & NAGEL] CO2 PURITY TESTER 10003 (CASE X) 10004 (CASE O)
닫기

비밀번호 인증

글 작성시 설정한 비밀번호를 입력해 주세요.

닫기

장바구니 담기

상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?

찜 리스트 담기

상품이 찜 리스트에 담겼습니다.
바로 확인하시겠습니까?

상단으로 이동