FM-140XL Digital Conductivity Meter

For direct reading of conductivity in %IACS

Applications

The FM-140XL meter is useful for sorting a wide variety of non-ferrous metals and alloys, as well as for measuring changes in physical properties reflecting conductivity.  Such changes include hardening, annealing, variations in alloy, heat treating corrosion and /or aging.

The FM-140XL delivers precise accuracy to ±.5% of the reading at 20°C.  Operating at 60kHz, the FM-140XL covers a range from 10 to 100 % IACS.  This meets or exceeds all present industry conductivity requirements including BAC 5651.

 

1.0    Description

1.1       The Model FM-140XL Digital Conductivity Meter is a microprocessor based electronic testing instrument which utilizes induced eddy currents to measure directly the electrical conductivity of nonmagnetic metals such as copper, aluminum, brass, molybdenum, nickel, tin or zinc, in units of percent International Annealed Copper Standard (%IACS).  It can also provide an indirect measurement of properties directly related to conductivity, such as heat treat condition or precipitation hardening of aluminum alloys, phosphorous content and thermal conductivity of copper.

1.2       The shielded probe, energized by 60 KHz  alternating current, induces circulating currents in the part to be measured.  These induced currents which are a function of conductivity, react back on the probe.  This reaction is then amplified and displayed.  A threshold gate can be set from the front panel to allow simple go/no go sorting.  Two conductivity samples are permanently mounted to the top of the unit for ease of set-up.  A 9-pin connector is available on the rear of the unit to allow for RS-232 type communications.

 

2.0     Mechanical and Construction

2.1       Dimensions:  2.75” (7 cm) high x 8.5” (21.6 cm) wide x 9” (22.9 cm) deep

2.2       Weight:  5.0 lbs. (2.27 kg)

2.3       Readout:  3-½ digits, .43” (1.09 cm) seven segment LED display

2.4       The FM-140XL is housed in a compact lightweight and shock resistant case for long life and durability.  A protective carrying case with storage pouch for probe and charger is available. 

 

3.0     Electrical and Performance

3.1       The FM-140XL is state-of-art design employing high reliability microprocessor and integrated circuits.

3.2       Frequency:    60 KHz

3.3       Range:   10% to 110% IACS

3.4       Accuracy is ± 0.5% IACS at 68oF (20oC)

3.5       Power Requirements:  The FM-140XL operates from two internal nickel cadmium battery packs of 6 volts each or from 120/240 volts, AC, 50/60 Hz power. 

3.6       The battery charger is a wall mounted transformer type capable of operating at 120/240 VAC.

3.7       The batteries are rated for approximately 10 hours continuous operation from the fully charged state, at 70o F, before recharging is necessary.  The recharge time required is 10 to 14 hours.

3.8       RS-232 port at rear of the unit.  A simple instruction set enables conductivity values to be loaded into separate computer, micro-controller, etc.

 

4.0     Operation

4.1       For initial calibration, the ON button is push to energize the unit.  The high calibration is set by placing the probe on the high calibration conductivity sample and pressing the up/down  arrow until the unit readout and the value of the sample are the same.  This procedure is then repeated for the low sample.  The unit is then ready to use.  An internal timer warns the operator to verify the calibration of the unit every fifteen minutes.  If the unit is left on and no readings are taken in that fifteen minute interval, the unit will shut off to conserve battery life.  The calibration information is saved in memory.

4.2       For gate operation, the procedure is very much the same.  The unit is turned on and calibrated.  The GATE ON and SET buttons are pushed.  To set the low threshold, push the LOW button and then the up/down arrows to the desired level.  The same is done on the high end.  The GATE SET button is again pushed.  Now when the probe is placed on a sample of material whose conductivity value is within the set high and low limits, the green LED on the front panel will light.  If the value is outside the limits set, the red LED will light.

 

5.0    Order Reference

5.1       Model FM-140XL Digital Conductivity Unit, including calibration samples, line cord, probe, and operating manual to operate on 115/60/1,  P/N 220220A

 

5.2       Standard Accessories

5.2.1    Calibration Samples:  Copper,  P/N 518542

                                                Brass,  P/N 518543

5.2.2    Battery Charger,  P/N 520239

5.2.3    Standard Probe,  P/N 220245

 

5.3       Addendum Accessories

5.3.1    Carrying Case,  P/N 519739

배송안내

- 배송비 : 기본배송료는 2,500원 입니다. (도서,산간,오지 일부지역은 배송비가 추가될 수 있습니다)  50,000원 이상 구매시 무료배송입니다.

- 본 상품의 평균 배송일은 0일입니다.(입금 확인 후) 설치 상품의 경우 다소 늦어질수 있습니다.[배송예정일은 주문시점(주문순서)에 따른 유동성이 발생하므로 평균 배송일과는 차이가 발생할 수 있습니다.]

- 본 상품의 배송 가능일은 0일 입니다. 배송 가능일이란 본 상품을 주문 하신 고객님들께 상품 배송이 가능한 기간을 의미합니다. (단, 연휴 및 공휴일은 기간 계산시 제외하며 현금 주문일 경우 입금일 기준 입니다.)

교환 및 반품안내

- 상품 택(tag)제거 또는 개봉으로 상품 가치 훼손 시에는 상품수령후 7일 이내라도 교환 및 반품이 불가능합니다.

- 저단가 상품, 일부 특가 상품은 고객 변심에 의한 교환, 반품은 고객께서 배송비를 부담하셔야 합니다(제품의 하자,배송오류는 제외)

- 일부 상품은 신모델 출시, 부품가격 변동 등 제조사 사정으로 가격이 변동될 수 있습니다.

- 신발의 경우, 실외에서 착화하였거나 사용흔적이 있는 경우에는 교환/반품 기간내라도 교환 및 반품이 불가능 합니다.

- 수제화 중 개별 주문제작상품(굽높이,발볼,사이즈 변경)의 경우에는 제작완료, 인수 후에는 교환/반품기간내라도 교환 및 반품이 불가능 합니다. 

- 수입,명품 제품의 경우, 제품 및 본 상품의 박스 훼손, 분실 등으로 인한 상품 가치 훼손 시 교환 및 반품이 불가능 하오니, 양해 바랍니다.

- 일부 특가 상품의 경우, 인수 후에는 제품 하자나 오배송의 경우를 제외한 고객님의 단순변심에 의한 교환, 반품이 불가능할 수 있사오니, 각 상품의 상품상세정보를 꼭 참조하십시오. 

환불안내

- 상품 청약철회 가능기간은 상품 수령일로 부터 7일 이내 입니다.

AS안내

- 소비자분쟁해결 기준(공정거래위원회 고시)에 따라 피해를 보상받을 수 있습니다.

- A/S는 판매자에게 문의하시기 바랍니다.

이미지 확대보기[CENTURION] 도전율측정기[금속전도도측정기] FM-140XL

[CENTURION] 도전율측정기[금속전도도측정기] FM-140XL
  • [CENTURION] 도전율측정기[금속전도도측정기] FM-140XL
닫기

비밀번호 인증

글 작성시 설정한 비밀번호를 입력해 주세요.

닫기

장바구니 담기

상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?

찜 리스트 담기

상품이 찜 리스트에 담겼습니다.
바로 확인하시겠습니까?

상단으로 이동